Skip to content

Signature scheduling

Time-dependent signature selection targets a particular signature or group for a configured time window. Configure this through the current Rules/Scheduling controls exposed by the installed release; older versions may display a separate Schedules section. Administrators set the start, end, optional domain scope and priority.

  • The start time must precede the end time.
  • Time windows are persisted in UTC; interpret local times carefully when crossing daylight-saving boundaries.
  • Before the start and after the end, normal selection applies.
  • During an active window, a matching time-constrained rule can take precedence over an otherwise eligible always-on rule.
  • Overlapping windows resolve through defined domain scope and priority ordering rather than random choice.

Example: a seasonal signature from December 1 at 00:00 through December 27 at 00:00 in the intended timezone. Verify the actual UTC representation. The API reference describes scheduling endpoints.